Operating temperature up to +150°C (+302°F)
Provides electromagnetic shielding
Self-wrapping design
Stable woven construction
Multiple grounding options available
FUNCTION:
• Instrument panel harnesses
• Engine compartment harnesses
• Battery cables
• Interior harnesses
Nominal Diameter (mm) | Recommended Application Range (mm) Min Ø Max Ø |
|---|---|
5 |
1 5 |
8 |
6 8 |
10 |
9 10 |
13 |
11 13 |
16 |
14 16 |
19 |
17 19 |
25 |
20 25 |
38 |
26 38 |
Max diameter is defined as a nominal 90° sleeve overwrap. A variety of application-based variables will dictate the appropriate sleeve size for use on each harness. Proper sleeve sizing is at the discretion of the end user.
A reduced overlap could be acceptable in certain applications allowing for a larger max diameter harness. Please consult your local sales representative for recommendations and guidance.
There are no installation guides available at this time. Please contact your sales representative or distribution team for further support.
For optimal viewing experience on a mobile device, rotate to a landscape orientation.
Property | Test Method | Result |
|---|---|---|
Temperature Rating | 240 hours at +175°C (+150°C rating) | Pass +150°C (+302°F) |
Low Temperature Flexibility | SAE J2192 | Pass -40°C (-94°F) |
Flammability | SAE J369 | Self-extinguishing |
Fluid Resistance | SAE J2192 | Pass |