Flame Protection of +1000°C (+1832°F) x 10minutes
Low voltage wiring in EV battery pack
Efficient level of thermal insulation (+600°C / +1112°F)
Highly thin, flexible and easy to install
Customized designs for custom fit
Contamination free composite structure
FUNCTIONS:
• BESS Wire Harnesses
• Server Rack Routing
• Thermal Runaway Protection
This product is designed to customer specific application, geometry and performance requirements. Due to the nature of this custom product, please consult your local sales representative for more details.
There are no installation guides available at this time. Please contact your sales representative or distribution team for further support.
For optimal viewing experience on a mobile device, rotate to a landscape orientation.
Property | Test Method | Result |
|---|---|---|
Thermal Runaway | SP Internal Test Method | Resists 10 min x +1000°C (+1832°F) Flame |
Thermal Insulation during +1000°C (+1832°F) x 10min flame | SP Internal Test Method | +500°C (+932°F) thermal insulation when mounted on steel plate |
Dielectric Strength Initial | EN6059-501 | 20kV/mm |
Electrical Insulation: Initial and Post Thermal Runaway | 1000V DC applied | >4000 MΏ |
Thickness | ASTM D1777 | 0.20mm without release liner |
Density | ASTM D1777; D3776; D3776M | 1.4 g/cm3 |
Thermal Conductivity | ASTM D1530-19 | 0.26 [W/m.k] |